Product Description
Autel MaxiSys MSOAK Oscilloscope Accessory Kit compatible with MSULTRA / MS919 / MP408, includes the 65A AC/DC current clamp, 650A AC/DC current clamp, coil on plug probe, HT extension lead (2pcs) and battery clip (2pcs), and a blow-molded carrying case.
Autel MaxiSys MSOAK Oscilloscope Accessory Kit
Autel MaxiSys MSOAK Description:
• Compatible with the MSULTRA, MS919 & MP408
• Includes 65A AC/DC current clamp, 650A AC/DC current clamp, coil on plug probe, HT Extension Lead (2pcs) and Battery Clip (2pcs)
• Includes Carrying Case
• Includes 1-Year Warranty
MaxiSys MSOAK Kit Details:
65A AC/DC current clamp
Introduction
When measuring AC or DC with the Current Clamp, you can connect it with a multimeter or an oscilloscope to directly read the current value without the need to make physical contact with the conductor or to disconnect it for insertion through the probe. The Current Clamp measures a maximum current of 65A, with a frequency up to 20 kHz. It works with jaws that open to allow clamping around an electrical conductor. After linking it with a multimeter or an oscilloscope, push down the zero adjustment knob on the clamp until the multimeter or oscilloscope reads zero.
How to use
1. Connect the BNC connector of the clamp to the input of a multimeter or an oscilloscope with an input impedance of at least 10k ohms.
2. When the current is no greater than 20A, set the current clamp to the range of 1mV/10mA, otherwise to 1mV/100mA. The green LED lights, indicating that the clamp is switched on.
3. Before measuring DC, please push down the zero adjustment knob on the clamp until the multimeter or oscilloscope reads zero. When using an oscilloscope, set DC coupled mode to measure DC.
4. Clamp the jaws around the electrical conductor
5. When the current clamp is set to 1 mV/10mA, the actual current value is ten times of the measured data whose unit is mV. For example, the measured data is 10 mV and the actual current is 10x10=100mA.
6. When the current clamp is set to 1 mV/100mA, the actual current is one hundred times of the measured data whose unit is m\Z For example, the measured data is 5 mV and the actual current is 5x100=500mA.
Notes:
1. In the case of DC measurement, the output is positive when the current flows from the upside to the underside of the clamp.
2. In the case of DC measurement, the current clamp may not be zeroed, due to the hysteresis effect, lb eliminate its influence, open and close the jaws several times before zeroing the current clamp.
Safety:
1. The voltage of the conductor measured cannot exceed 300V DC or 240V RMS AC.
2. You cannot measure a piece of a conductor whose insulation is broken or worn to avoid possible electric shock.
General Specifications
Conductor Diameter: 9mm maximum
Low Battery Indicator: Red LED
Operating Temperature: OC to 50C, 70% R.H.
Storage Temperature: -20C〜+70C, 80% R.H.
Battery type: 9V DC, NEDA 1604, 6F22, 006P
Battery Life: 100 hours typical with carbon-zinc
Weight: 250 grams
Dimensions: 195 mm (H) x 70 mm (W) x 33 mm (D)
Output: Through a BNC connector
ELECTRICAL (At 23±5C,70% R.H. maximum)
Efficient Measure Range:
1 mV/10mA: 10mA to 20 A DC or RMS AC
1 mV/100mA: 100mA to 65 A DC or RMS AC
650A AC/DC current clamp
Introduction
When measuring AC or DC with the Current Clamp, you can connect it with a multimeter or an oscilloscope to directly read the current value without the need to make physical contact with the conductor, or to disconnect it for insertion through the probe. The Current Clamp measures a maximum current of 650A, with a frequency up to 400Hz. It works with jaws which open to allow clamping around an electrical conductor. After linking it with a multimeter or an oscilloscope, push down the zero adjustment knob on the clamp until the multimeter or oscilloscope reads zero.
How to use
1. Connect the BNC connector of the clamp to the input of a multimeter or an oscilloscope with an input impedance of at least 10k ohms.
2. When the current is no greater than 200A, set the current clamp to the range of 1 mV/1 OmA, otherwise to 1 mV/1A. The green LED lights, indicate that the clamp is switched on.
3. Before measuring DC, please push down the zero adjustment knobs on the clamp until the multimeter or oscilloscope reads zero. When using an oscilloscope, set DC-coupled mode to measure DC.
4. Clamp the jaws around the electrical conductor.
5. When the current clamp is set to 1 mV/100mA, the actual current value is one hundred times the measured data whose unit is mV. For example, the measured data is 10 mV and the actual current is 10x100=1000mA.
6. When the current clamp is set to 1 mV/1A, the actual current is one thousand times the measured data whose unit is mV. For example, the measured data is 5 mV and the actual current is 5x1000=5000mA.
Notes:
1. In the case of DC measurement, the output is positive when the current flows from the upside to the underside of the clamp.
2. In the case of DC measurement, the current clamp may not be zeroed, due to the hysteresis effect. Io eliminate its influence, open and close the jaws several times before zeroing the current clamp.
Safety:
1. The voltage of the conductor measured cannot exceed 300V DC or 240V RMS AC.
2. YDU cannot measure a piece of a conductor whose insulation is broken or worn to avoid possible electric shock.
General Specifications
Conductor diameter: 30mm maximum
Low Battery Indicator: Red LED
Operating Temperature: 0C to 50C, 70% R.H.
Storage Temperature: -20 C ~+70 C, 80% R.H.
Battery type: 9V DC, NEDA 1604, 6F22, 006P
Battery Life: 100 hours typical with carbon-zinc
Weight: 250 grams
Dimensions: 195 mm (H) x 70 mm (W) x 33 mm (D)
Output: Through a BNC connector
ELECTRICAL (At 23±5C, 70% R.H. maximum)
Efficient Measure Range:
1 mV/100mA: 100mA to 200A DC or RMS AC
1 mV/1 A: 1A to 650A DC or RMS AC
coil on plug probe
Features
• COP Probe can catch the ignition waveform of an automobile engine easily. The ignition waveform is a window, through which we can see what happened in the engine combustion chambers. It determines whether the ignition plug needs to be replaced or cleaned. Does fuel injector in electronic fuel injection system work well? Is there any problem with the leakproofness of the air cylinder? Does the gap between ignition plugs get larger? Does the electrode shape of the ignition plug become sharp? Is there too much oil pollution or carbon deposition on the ignition plugs? Does the insulating property of the ignition plug get worse? Is there any problem with the power supply system of the storage battery?
• It can be used with a normal oscilloscope. Special anti-interference design, high accuracy of measurement.
• Ergonomic design, can be arbitrarily curved.
• Highlight LED which is convenient to operate at night or in dark conditions.
Warning
• To avoid injury, keep the probe away from moving parts, such as the alternator drive belt and cooling fans.
• To present electric shock, do not use if the probe's sensor plate's insulation shows signs of damage.
Battery
Pay attention to the positive and negative polarity, as shown below.
MaxiSys MSOAK Package list:
1pc x 65A AC/DC Current Clamp
1pc x 65A AC/DC Current Clamp User Manual
1pc x 650A AC/DC Current Clamp
1pc x 650A AC/DC Current Clamp User Manual
1pc x Coil on Plug Probe
1pc x Coil on Plug Probe User Manual
2pcs x HT Extension Lead
2pcs x Battery Clip
1pc x Packing List
1pc x Carrying Case
Hot Branded Products:
Shipping method and delivery time:
UK Shipping: No Tax, 2-4 working days arrive. For products marked " UK Ship " and UK local customer
EU shipping: No Tax, 5-7 working days arrive. For products marked " EU Ship " and from EU countries, if not belong to EU, need to clearance
Yodel/Royal Post/herems: No tax, around 5-7 days arrive . For products UK out of stock, and customers from UK
Yanwen: No Tax, 7-14 working days arrive, ship to all over the world, mainly for UK/EU warehouse no stock
DHL: Has Tax, need to clearance, 3-5 working days arrive. Used for UK/EU no stock, customers request ship this way. Need to clearance, we will declare a low price on the invoice help to clearance.
If you have any questions about the device, the price, or the payment, please feel free to contact us.
Contact Person: Elyza
Whatsapp: +86 13983755934
Telephone: +86 13983755934
Wechat: +86 13983755934
Official Email: Sales@obd2shop.co.uk